ข้ามสารบัญไปยังเนื้อหา
อัปเดต 2026-09-07
Datasheets & export
FM-EN-17
Turn a solved element into a vendor-ready FM-EN-17 datasheet, or export the whole study — gated by the honesty banners so a blocked result can never be datasheeted.
เมื่อไรจึงใช้
- Issuing an RFQ / purchase spec for a sized pump, valve, PSV, or exchanger.
- Handing a solved model to a colleague, a stress package, or a client review.
- Capturing the calculation trail behind a number for audit.
ค่าที่ต้องกรอก
| ค่า | คำอธิบาย |
|---|---|
| Selected element | The solved node/pipe whose results populate the datasheet fields. |
| Cover overrides | Optional project / client / revision fields for the A4 cover. |
| Export format | FM-EN-17 PDF datasheet, calc sheet, or a whole-study PDF/Word/Excel/CSV/JSON. |
คำนวณอย่างไร
The result adapter maps engine outputs to the datasheet rows; a spec builder renders the A4 cover + operating conditions + calculation pages. Export buttons are disabled whenever the solve carries a blocking scope note, so an unsafe result cannot become a document.
ข้อควรระวัง
noteA blocking honesty banner (e.g. A1 relief, A36 slurry deposition) disables the datasheet button — clear the condition first.
noteGenuinely-uncomputed fields (mode-specific or kinetic terms) are left blank rather than fabricated.
ที่เกี่ยวข้อง