Tank

storage / level

A storage node with a level that (in an extended run) rises and falls as it fills or drains. In a steady solve it behaves like a fixed head at its current level.

เมื่อไรจึงใช้
  • Break tanks, surge tanks, day tanks — anywhere storage volume matters.
  • EPS-lite tank-vs-time studies where the level changes over the run.
ค่าที่ต้องกรอก
ค่าคำอธิบาย
Base elevation & levelHead = elevation + current liquid level.
Geometry (area / diameter)Used to convert net inflow into a level change over time.
คำนวณอย่างไร

Steady: fixed head at the current level. EPS-lite: net flow integrated over each timestep updates the level; emptied/overflowed states raise a loud scope note (A47/A48).

ข้อควรระวัง
noteA tank that empties or overflows during an EPS-lite run is flagged, not silently clamped.