DekEn

อัปเดต 2026-09-07

Junction & demand

interior node / draw

An interior node where pipes meet. It can carry a demand (a fixed draw or supply) or be a pure connector with zero demand.

เมื่อไรจึงใช้
  • Any tee, branch, or connection point inside the network.
  • A consumer draw (positive demand) or a distributed supply (negative demand) at a known flow.
ค่าที่ต้องกรอก
ค่าคำอธิบาย
DemandVolumetric draw (+) or supply (−). Zero = pure connector.
ElevationNode elevation — sets the static-head reference for pressure.
คำนวณอย่างไร

Continuity (Σ flows in = demand out) is enforced at every junction; the GGA solves the coupled head/flow system so all junction balances close simultaneously.

ข้อควรระวัง
noteA degree-1 junction with a demand is auto-reclassified to an open pipe on load — use Assign-Flowrate for an end-of-line draw so the demand survives.
ที่เกี่ยวข้อง