ข้ามสารบัญไปยังเนื้อหา
อัปเดต 2026-09-07
In-builder sizing tabs
size from the solve
Size equipment straight from a solved node — the node’s own solved pressure, temperature, and composition seed the sizing so you don’t re-key conditions into a separate calculator.
เมื่อไรจึงใช้
- Sizing a relief/bursting device or restriction against the actual local conditions at a node.
- Checking a flash or settle-out condition that the network solve just produced.
ค่าที่ต้องกรอก
| ค่า | คำอธิบาย |
|---|---|
| Solved node | Its pressure/temperature/phase seed the sizing tab automatically. |
| Device spec | Set pressure, back pressure, Kd/Cd, standard basis — per the tab. |
คำนวณอย่างไร
Each tab runs the matching engine on the seeded conditions: free-water V-L-L flash, compressor/pump-trip settle-out pressure, flashing / two-phase relief (API 520 Omega), bursting-disk, gas-relief, ISO-5167 orifice, and heat-exchanger sizing.
ข้อควรระวัง
noteA sub-atmospheric or out-of-envelope node can make a device request refuse (clean 4xx) rather than return a number — that is the correct-or-loud guard, not a bug.
ที่เกี่ยวข้อง