Transient panel & scenarios

setup / run

The Transient panel defines scenarios (valve closures, pump trips, startups) on top of a converged steady state and runs the MOC in the time domain.

เมื่อไรจึงใช้
  • Surge analysis, valve-closure studies, pump-trip protection design.
ค่าที่ต้องกรอก
ค่าคำอธิบาย
ScenarioEvent type + timing (e.g. valve closure over 5 s, linear/exponential/two-stage).
Duration & wave speedSimulation time and pipe wave speed (or elastic properties).
คำนวณอย่างไร

The water-hammer PDEs are solved by the Method of Characteristics on a grid where the Courant number equals 1, so wave transport is exact. At each interior point two characteristic equations (C+ and C−) combine to give the new head and flow; boundaries and junctions close the system. A converged steady solve provides the initial condition.

สมการ
Characteristic compatibility equations
Solved together at each node: adding gives H_P, subtracting gives Q_P.
Constants
B = characteristic impedance (a = wave speed, A = area), R = friction resistance per reach. C_P, C_M carry the upstream/downstream H, Q and the R Q|Q| friction term.
ข้อควรระวัง
noteScenarios and config persist across reloads; a valve closure pattern is honored exactly (a past bug slammed every API closure at t=0 — fixed).